Datasheet
TSH24
2/11
SCHEMATIC DIAGRAM (1/4 TSH24)
ABSOLUTE MAXIMUM RATINGS
OPERATING CONDITIONS
Symbol Parameter Value Unit
V
CC
Supply Voltage ±18 to 36 V
V
id
Differential Input Voltage
1)
±36 V
V
i
Input Voltage (see note 1) ±18 V
Output Short-circuit Duration
2)
Infinite
T
oper
Operating Free-Air Temperature Range -40 to +125 °C
T
j
Maximum Junction Temperature +150 °C
T
stg
Storage Temperature Range -65 to +150 °C
p
tot
Maximum Power Dissipation (see note 2) 500 mW
1. Either or both input voltages must not exceed the magnitude of V
CC
+
or V
CC
-
2. Power dissipation must be considered to ensure maximum junction temperature (T
j
) is not exceeded
Symbol Parameter Value Unit
V
CC
Supply Voltage 3 to 30 V
V
id
0mV
A
vd
R
L
= 2k
Ω
100 dB
I
cc
No load, each amplifier 2 mA
Vicm -15.2 to 13.8 V
V
OH
R
L
= 2k
Ω
+13.9 V
V
OL
R
L
= 2k
Ω
-13.9 V
I
sink
V
o
= 0V
40 mA
I
source
V
o
= 0V
40 mA
GBP
R
L
= 2k
Ω,
C
L
= 100pF
34 MHz
SR
R
L
= 2k
Ω,
C
L
= 100pF
10 V/
µ
s
∅
m
R
L
= 2k
Ω,
C
L
= 100pF
36 Degrees
∅
m
R
L
= 2k
Ω,
C
L
= 300pF
26 Degrees