Datasheet

Absolute maximum ratings and operating conditions TSH110-TSH111-TSH112-TSH113-TSH114
2/15
1 Absolute maximum ratings and operating conditions
Table 1. Absolute maximum ratings (AMR
Symbol Parameter Value Unit
V
CC
Supply voltage
(1)
1. All voltage values, except differential voltage, are with respect to network ground terminal.
14 V
V
id
Differential input voltage
(2)
2. Differential voltages are the non-inverting input terminal with respect to the inverting terminal.
±1 V
V
i
Input voltage
(3)
3. The magnitude of input and output voltages must never exceed V
CC
+0.3V
±6 V
T
oper
Operating free air temperature range -40 to +85 °C
T
stg
Storage temperature -65 to +150 °C
T
j
Maximum junction temperature 150 °C
R
thjc
Thermal resistance junction to case
SOT23-5
SO-8
SO-14
TSSOP8
TSSOP14
80
28
22
37
32
°C/W
R
thja
Thermal resistance junction to ambiant area
SOT23-5
SO-8
SO-14
TSSOP8
TSSOP14
250
157
125
130
110
°C/W
ESD
HBM: human body model
(4)
4. Human body model: A 100pF capacitor is charged to the specified voltage, then discharged through a
1.5kΩ resistor between two pins of the device. This is done for all couples of connected pin combinations
while the other pins are floating.
2.0
kVMM: machine model
(5)
5. Machine model: A 200pF capacitor is charged to the specified voltage, then discharged directly between
two pins of the device with no external series resistor (internal resistor < 5Ω). This is done for all couples of
connected pin combinations while the other pins are floating.
0.2
CDM: charged device model
(6)
6. Charged device model: all pins and the package are charged together to the specified voltage and then
discharged directly to the ground through only one pin. This is done for all pins.
1.5
Output short circuit duration
(7)
7. Short-circuits can cause excessive heating and can result in destructive dissipation.
Table 2. Operating conditions
Symbol Parameter Value Unit
V
CC
Supply voltage 5 to 12 V
V
icm
Common mode input voltage range V
CC
-
+1.5 to V
CC
+
-1.5 V