Datasheet
TSC103 Electrical characteristics
Doc ID 16873 Rev 2 9/26
Table 7. Frequency response
Symbol Parameter Test conditions Min. Typ. Max. Unit
ts
Response to input differential
voltage change.
Output settling to 1% of final value
V
sense
square pulse applied to
generate a variation of Vout
from 500 mV to 3 V
C
load
=47pF
Av = 20 V/V, 3 µs
Av = 25 V/V 4 µs
Av = 50 V/V 6 µs
Av = 100 V/V 10 µs
t
SEL
Response to a gain change.
Output settling to 1% of final value
Any change of state of SEL1
or SEL2 pin
1µs
t
rec
Response to common-mode
voltage change.
Output settling to 1% of final value
V
cc+
=5V, V
cc-
=-5V
V
m
step change from -2 V to
30 V or 30 V to -2 V
20 µs
SR Slew rate V
sense
=10mV to 100mV 0.4 0.6 V/µs
BW 3 dB bandwidth
C
load
=47pF V
m
=12V
V
sense
=50mV
Av = 50 V/V
700 kHz
Table 8. Noise
Symbol Parameter Test conditions Min. Typ. Max. Unit
e
N
Equivalent input noise voltage f = 1 kHz 40 nV/√ Hz