Datasheet

DocID023340 Rev 2 5/21
TS881 Absolute maximum ratings and operating conditions
21
1 Absolute maximum ratings and operating conditions
Table 1. Absolute maximum ratings
Symbol Parameter Value Unit
V
CC
Supply voltage
(1)
1. All voltage values, except differential voltages, are referenced to V
CC
-. V
CC
is defined as the difference
between V
CC
+ and V
CC
-.
6V
V
ID
Differential input voltage
(2)
2. The magnitude of input and output voltages must never exceed the supply rail ±0.3 V.
±6 V
V
IN
Input voltage range (V
CC
-) - 0.3 to (V
CC
+) + 0.3 V
R
THJA
Thermal resistance junction-to-ambient
(3)
SC70-5
SOT23-5
3. Short-circuits can cause excessive heating. These values are typical.
205
250
°C/W
T
STG
Storage temperature -65 to +150 °C
T
J
Junction temperature 150 °C
T
LEAD
Lead temperature (soldering 10 seconds) 260 °C
ESD
Human body model (HBM)
(4)
4. According to JEDEC standard JESD22-A114F.
8000 kV
Machine model (MM)
(5)
5. According to JEDEC standard JESD22-A115A.
300
V
Charged device model (CDM)
(6)
6. According to ANSI/ESD STM5.3.1.
1300
Latch-up immunity 200 mA
Table 2. Operating conditions
Symbol Parameter Value Unit
T
oper
Operating temperature range
0.85 V < V
CC
< 5.5 V
1.1 V < V
CC
< 5.5 V
-40 to +85
-40 to +125
°C
V
CC
Supply voltage
-40 °C < T
amb
< +85 °C
-40 °C < T
amb
< +125 °C
0.85 to 5.5
1.1 to 5.5
V
V
ICM
Common mode input voltage range
0.85 V < V
CC
< 5.5 V
-40 °C < T
amb
< +85 °C
1.1 V < V
CC
< 5.5 V
-40 °C < T
amb
< +85 °C
-40 °C < T
amb
< +125 °C
- 0.2 to + 0.2 and
V
CC+
- 0.2 to V
CC+
+0.2
V
CC-
- 0.2 to V
CC+
+0.2
V
CC-
to V
CC+
+0.2
V