Datasheet

TS831
2/11
ABSOLUTE MAXIMUM RATINGS
OPERATING CONDITIONS
TS831-5
ELECTRICAL CHARACTERISTICS Tamb = 25°C (unless otherwise specified)
Symbol Parameter Value Unit
V
CC
Supply Voltage
1)
7V
V
OUT
Output Voltage
-0.3 to V
cc
+ 0.3
V
I
OUT
Output Sink Current TS831-5 and TS831-4
TS831-3
20
5
mA
P
D
Power Dissipation
2)
TO92
SO8
TSSOP8
625
700
625
mW
I
F
Clamp Diode Forward Current, pin 1 to pin 2
3)
100 mA
T
STG
Storage Temperature -65 to +150 °C
1. All voltages values, except differential voltage are with respect to network ground terminal.
2. T
j
= 150°C, T
amb
= 25
o
C with Rthja = 200
o
C/W for TO-92 package
Rthja = 175
o
C/W for SO8 package
Rthja = 200
o
C/W for TSSOP8 package
3. Maximum package power dissipation limits must be observed.
Symbol Parameter Value Unit
V
CC
Supply Voltage 1 to 5.5 V
T
OPER
Operating Free Air Temperature Range -40 to +125 °C
Symbol Parameter Min. Typ. Max. Unit
V
THI
Threshold Voltage with V
CC
Increasing
-40°C
Tam b
+85°C
-40°C
Tam b
+125°C
4.11
4.11
4.33
4.46
4.50
V
V
THD
Threshold Voltage with V
CC
Decreasing
-40°C
Tam b
+85°C
-40°C
Tam b
+125°C
4.10
4.06
4.21
4.46
4.46
V
V
HYS
Hysteresis Voltage 50 100 200 mV
I
CC
Current Consumption V
CC
= 5V
12
µ
A
V
OL
Low Level Output Voltage V
CC
= 4V, I
OL
= 8mA
-40°C
Tam b
+85°C
-40°C
Tam b
+125°C
450 800
1000
1300
mV
I
OH
High Level Output Current V
CC
= 5V
-40°C
Tam b
+125°C
2 100
1000
nA
T
PHL
Response Time High to Low
R
L
= 10k
, C
L
= 15pF, V
CC
= V
THD
-10mV
20
µ
s
Note : Limits are 100% production tested at 25°C. Limits over temperature are guaranteed through correlation and by design.