Datasheet
Macromodel TS512, TS512A
12/18 Doc ID 4948 Rev 5
Table 4. V
CC
= ±15 V, T
amb
= 25 °C (unless otherwise specified)
Symbol Conditions Value Unit
V
io
0mV
A
vd
R
L
= 2 kΩ 100 V/mV
I
CC
No load, per operator 350 µA
V
icm
-13.4 to 14 V
V
OH
R
L
= 2 kΩ +14 V
V
OL
R
L
= 2 kΩ -14 V
I
sink
V
o
= 0 V 27.5 mA
I
source
V
o
= 0 V 27.5 mA
GBP R
L
= 2 kΩ, C
L
= 100 pF 2.5 MHz
SR R
L
= 2 kΩ 1.4 V/μs
∅mR
L
= 2 kΩ, C
L
= 100 pF 55 Degrees