Datasheet

Absolute maximum ratings and operating conditions TS4962
4/44 Doc ID 10968 Rev 8
Table 3. Operating conditions
Symbol Parameter Value Unit
V
CC
Supply voltage
(1)
1. For V
CC
between 2.4 V and 2.5 V, the operating temperature range is reduced to 0°C T
amb
70°C.
2.4 to 5.5 V
V
IC
Common mode input voltage range
(2)
2. For V
CC
between 2.4V and 2.5V, the common mode input range must be set at V
CC
/2.
0.5 to V
CC
-0.8 V
V
STBY
Standby voltage input:
(3)
Device ON
Device OFF
3. Without any signal on V
STBY
, the device will be in standby.
1.4 V
STBY
V
CC
GND
V
STBY
0.4
(4)
4. Minimum current consumption is obtained when V
STBY
= GND.
V
R
L
Load resistor 4 Ω
R
thja
Thermal resistance junction to ambient
DFN8 package
(5)
5. When mounted on a 4-layer PCB.
50 °C/W