Datasheet
Absolute Maximum Ratings and Operating Conditions TS4436
2/8
1 Absolute Maximum Ratings and Operating
Conditions
Table 1. Key parameters and their absolute maximum ratings
Symbol Parameter Value Unit
I
SINK
Output sink current 30 mA
V
CC
Supply voltage 12 V
V
SINK
Output voltage 12 V
P
diss
Power Dissipation
(1)
SOT23-5
1. P
diss
has been calculated with T
AMB
= 25°C, T
Junction
=150°C and
R
thJA
= 250°C/W for the SOT23-5 package
R
thJC
= 81°C/W for the SOT23-5 package
mW
P
diss
Power Dissipation
(2)
SC70
2. P
diss
has been calculated with T
AMB
= 25°C, T
Junction
=150°C and
R
thJA
= 250°C/W for the SOT23-5 package
R
thJC
= 81°C/W for the SOT23-5 package
310 mW
T
STD
Storage Temperature -65 to +150 °C
ESD
Human Body Model (HBM) 2 kV
Machine Model (MM) 200 V
T
LEAD
Lead Temperature (soldering, 10 seconds) 250 °C
Table 2. Operating conditions
Symbol Parameter Value Unit
T
OPER
Operating temperature range -40 to +85 °C
V
CC
Supply voltage 1.7 to 10 V
I
SINK
Output sink current up to 20 mA