Datasheet
TS391 Absolute maximum ratings and operating conditions
Doc ID 6324 Rev 6 3/12
2 Absolute maximum ratings and operating conditions
Table 1. Absolute maximum ratings (AMR)
Symbol Parameter Value Unit
V
CC
Supply voltage ±18 or 36 V
V
id
Differential input voltage ±36 V
V
i
Input voltage -0.3 to +36 V
Output short-circuit to ground
(1)
1. Short-circuits from the output to V
CC
+
can cause excessive heating and potential destruction. The
maximum output current is approximately 20 mA independent of the magnitude of V
CC
+
.
Infinite
T
j
Maximum junction temperature 150 °C
R
thja
Thermal resistance junction to ambient
(2)
SOT23-5
DFN8 2x2
2. Short-circuits can cause excessive heating. These values are typical.
250
57
°C/W
T
stg
Storage temperature range -65 to +150 °C
ESD
Human body model (HBM)
(3)
3. Human body model: a 100 pF capacitor is charged to the specified voltage, then discharged through a
1.5 kΩ resistor between two pins of the device. This is done for all couples of connected pin combinations
while the other pins are floating.
1500
VMachine model (MM)
(4)
4. Machine model: a 200 pF capacitor is charged to the specified voltage, then discharged directly between
two pins of the device with no external series resistor (internal resistor < 5 Ω). This is done for all couples of
connected pin combinations while the other pins are floating.
100
Charged device model (CDM)
(5)
5. Charged device model: all pins and package are charged together to the specified voltage and then
discharged directly to ground through only one pin. This is done for all pins.
1000
Table 2. Operating conditions
Symbol Parameter Value Unit
V
CC
Supply voltage 2 to 36 or ±1 to ±18 V
V
icm
Input common mode voltage range
(1)
T
amb
= 25°C
T
min
≤ T
amb
≤ T
max
1. The input common-mode voltage of either input signal voltage should not be allowed to go negative by
more than 0.3 V. The upper end of the common-mode voltage range is V
CC
+
–1.5 V, but either or both
inputs can go to +30 V without damage.
0 to V
CC
+
-1.5
0 to V
CC
+
-2
V
T
oper
Operating free-air temperature range -40 to +125 °C