Datasheet
TS372 Absolute maximum ratings and operating conditions
Doc ID 4068 Rev 2 3/10
2 Absolute maximum ratings and operating conditions
Table 1. Absolute maximum ratings
Symbol Parameter Value Unit
V
CC
+ Supply voltage
(1)
(2)
1. Maximum power supply voltage when the comparator is not switching.
2. All voltage values, except differential voltage, are with respect to network ground terminal.
18 V
V
id
Differential input voltage
(3)
3. Differential voltages are the non-inverting input terminal with respect to the inverting input terminal.
±18 V
V
i
Input voltage
(4)
4. The magnitude of the input and the output voltages must never exceed the magnitude of the positive
supply voltage.
18 V
V
o
Output voltage 18 V
I
o
Output current 20 mA
I
F
Forward current in ESD protection diodes on input
(5)
5. Guaranteed by design.
50 mA
Duration of output circuit to GND
(6)
6. Short-circuit from outputs to Vcc+ can cause excessive heating and eventual destruction.
Infinite
p
d
Power dissipation
(7)
DIP8
SO8
7. Pd is calculated with T
amb
= +25°C, T
j
= +150°C and R
thja
= 100°C/W for DIP8 package = 175°C/W for
SO-8 package.
1250
710
mW
T
stg
Storage temperature range -65 to +150 °C
T
j
Junction temperature +150 °C
Table 2. Operating conditions
Symbol Parameter Value Unit
V
CC
+ Supply voltage 3 to 16 V
Vicm
Input common-mode voltage range
(1)
T
amb
= 25°C
T
min
≤ T
amb
≤ T
max
TS372C
TS372I/TS372M
1. And input voltages < = 12 V.
V
CC
+
-2
V
CC
+
-2.25
V
CC
+
-2.5
V
T
oper
Operating free-air temperature range
TS372C
TS372I
TS372M
0 to +70
-40 to +125
-55 to +125
°C