Datasheet
TS321 Macromodel
Doc ID 6298 Rev 8 9/15
VIP 4 18 2.000000E+00
FCP 4 5 VOFP 3.400000E+01
FCN 5 4 VOFN 3.400000E+01
FIBP 2 5 VOFN 2.000000E-03
FIBN 5 1 VOFP 2.000000E-03
* AMPLIFYING STAGE
FIP 5 19 VOFP 3.600000E+02
FIN 5 19 VOFN 3.600000E+02
RG1 19 5 3.652997E+06
RG2 19 4 3.652997E+06
CC 19 5 6.000000E-09
DOPM 19 22 MDTH 400E-12
DONM 21 19 MDTH 400E-12
HOPM 22 28 VOUT 7.500000E+03
VIPM 28 4 1.500000E+02
HONM 21 27 VOUT 7.500000E+03
VINM 5 27 1.500000E+02
EOUT 26 23 19 5 1
VOUT 23 5 0
ROUT 26 3 20
COUT 3 5 1.000000E-12
DOP 19 25 MDTH 400E-12
VOP 4 25 2.242230E+00
DON 24 19 MDTH 400E-12
VON 24 5 7.922301E-01
.ENDS
4.3 Electrical characteristics of the macromodel
Table 4. Electrical characteristics at V
CC
+
= +3 V, V
CC
-
= 0 V, R
L
, C
L
connected to
V
CC
/2, T
amb
= 25 °C (unless otherwise specified)
Symbol Conditions Value Unit
V
io
0mV
A
vd
R
L
= 2 kΩ 100 V/mV
I
CC
No load, per operator 300 µA
V
icm
0 to +3.5 V
V
OH
R
L
= 2 kΩ 3.5 V
V
OL
R
L
= 2 kΩ 5mV
I
os
V
o
= 0 V 40 mA
GBP R
L
= 2 kΩ, C
L
= 100 pF 0.8 MHz
SR R
L
= 2 kΩ, C
L
= 100 pF 0.4 V/μs
∅mR
L
= 2 kΩ, C
L
= 100 pF 60 Degrees