Datasheet
TL084 - TL084A - TL084B
2/12
SCHEMATIC DIAGRAM (each amplifier)
ABSOLUTE MAXIMUM RATINGS
Symbol Parameter TL084M, AM, BM TL084I, AI, BI TL084C, AC, BC Unit
V
CC
Supply voltage - note
1)
1. All voltage values, except differential voltage, are with respect to the zero reference level (ground) of the supply voltages where the zero reference
level is the midpoint between V
CC
+
and V
CC
-
.
±18 V
V
i
Input Voltage - note
2)
2. The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 15 volts, whichever is less.
±15 V
V
id
Differential Input Voltage - note
3)
3. Differential voltages are the non-inverting input terminal with respect to the inverting input terminal.
±30 V
P
tot
Power Dissipation 680 mW
Output Short-circuit Duration - note
4)
4. The output may be shorted to ground or to either supply. Temperature and/or supply voltages must be limited to ensure that the dissipation rating
is not exceeded
Infinite
T
oper
Operating Free-air Temperature Range -55 to +125 -40 to +105 0 to +70 °C
T
stg
Storage Temperature Range -65 to +150 °C
Output
Non-inverting
input
Inverting
input
V
CC
V
CC
200
Ω
Ω
100
Ω
100
1.3k
30k
35k
35k
Ω
100
1.3k
8.2k