Absolute maximum ratings and operating conditions TL074
4/18 DocID2297 Rev 5
2 Absolute maximum ratings and operating conditions
Table 1. Absolute maximum ratings
Symbol Parameter
Value
Unit
TL074I, AI, BI TL074C, AC, BC
V
CC
Supply voltage
(1)
±18
VV
i
Input voltage
(2)
±15
V
id
Differential input voltage
(3)
±30
P
tot
Power dissipation 680 mW
R
thja
Thermal resistance junction to ambient
(4)(5)
SO14 105
°C/W
R
thjc
Thermal resistance junction to case
(4)(5)
SO14 31
Output short-circuit duration
(6)
Infinite
T
oper
Operating free-air temperature range -40 to +125 0 to +70
°C
T
stg
Storage temperature range -65 to +150
ESD
HBM: human body model
(7)
1kV
MM: machine model
(8)
200 V
CDM: charged device model
(9)
1.5 kV
1. All voltage values, except differential voltage, are with respect to the zero reference level (ground) of the supply voltages
where the zero reference level is the midpoint between V
CC
+
and V
CC
-
.
2. The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 15 volts, whichever is less.
3. Differential voltages are the non-inverting input terminal with respect to the inverting input terminal.
4. Short-circuits can cause excessive heating. Destructive dissipation can result from simultaneous short-circuits on all
amplifiers.
5. Rth are typical values.
6. The output may be shorted to ground or to either supply. Temperature and/or supply voltages must be limited to ensure
that the dissipation rating is not exceeded.
7. Human body model: 100pF discharged through a 1.5kΩ resistor between two pins of the device, done for all couples of pin
combinations with other pins floating.
8. Machine model: a 200pF cap is charged to the specified voltage, then discharged directly between two pins of the device
with no external series resistor (internal resistor < 5Ω), done for all couples of pin combinations with other pins floating.
9. Charged device model: all pins plus package are charged together to the specified voltage and then discharged directly to
the ground.
Table 2. Operating conditions
Symbol Parameter TL074I, AI, BI TL074C, AC, BC Unit
V
CC
Supply voltage 6 to 36 V
T
oper
Operating free-air temperature range -40 to +125 0 to +70 °C