Datasheet
Table Of Contents
- 1 Schematic diagram
- 2 Absolute maximum ratings and operating conditions
- 3 Electrical characteristics
- Table 3. VCC = ±15 V, Tamb = +25 °C (unless otherwise specified)
- Figure 2. Maximum peak-to-peak output voltage versus frequency
- Figure 3. Maximum peak-to-peak output voltage versus frequency
- Figure 4. Maximum peak-to-peak output voltage versus frequency
- Figure 5. Maximum peak-to-peak output voltage versus free air temperature
- Figure 6. Maximum peak-to-peak output voltage versus load resistance
- Figure 7. Maximum peak-to-peak output voltage versus supply voltage
- Figure 8. Input bias current versus free air temperature
- Figure 9. Large signal differential voltage amplification versus free air temperature
- Figure 10. Large signal differential voltage amplification and phase shift versus frequency
- Figure 11. Total power dissipation versus free air temperature
- Figure 12. Supply current per amplifier versus free air temperature
- Figure 13. Common mode rejection ratio versus free air temperature
- Figure 14. Voltage follower large signal pulse response
- Figure 15. Output voltage versus elapsed time
- Figure 16. Equivalent input noise voltage versus frequency
- Figure 17. Total harmonic distortion versus frequency
- 4 Parameter measurement information
- 5 Typical applications
- 6 Package information
- 7 Ordering information
- 8 Revision history

DocID2297 Rev 5 17/18
TL074 Revision history
18
8 Revision history
Table 6. Document revision history
Date Revision Changes
28-Mar-2001 1 Initial release.
30-Jul-2007 2
Added values for R
thja
,
R
thjc
and ESD in Table 1: Absolute maximum
ratings.
Added Table 2: Operating conditions.
Expanded Table 5: Order codes.
Format update.
07-Jul-2008 3
Removed information concerning military temperature ranges
(TL074Mx, TL074AMx, TL074BMx).
Added automotive grade order codes in Table 5: Order codes.
04-Jul-2012 4
Removed commercial types TL074IYD, TL074AIYD, TL074BIYD.
Updated Table 5: Order codes.
22-Nov-2013 5
Added Related products on first page
Removed DIP package mechanical information
Table 5: Order codes:
– removed commercial types related to DIP package: TL074IN,
TL074AIN, TL074BIN, TL074CN, TL074ACN, TL074BCN;
– removed commercial types related to tube packing: TL074ID,
TL074AID, TL074BID, TL074CD, TL074ACD, TL074BCD;
– changed operating temperature range for TL074IDT, TL074AIDT,
TL074BIDT, TL074IYDT, TL074AIYDT, TL074BIYDT from -40 °C,
+105 °C to -40 °C, +125 °C;
– updated footnote for automotive parts.