Datasheet

Table Of Contents
Typical applications TL074
12/18 DocID2297 Rev 5
Figure 22. Output A Figure 23. Output B
SECOND ORDER BANDPASS FILTER
fo = 100 kHz; Q = 30; Gain = 16
CASCADED BANDPASS FILTER
fo = 100 kHz; Q = 69; Gain = 16