Datasheet

TDA7269A
4/9
MUTE STAND-BY FUNCTION
The pin 5 (MUTE/STAND-BY) controls the amplifier status by two different thresholds, referred to +V
S
.
When V
pin5
higher than = +V
S
-2.5V the amplifier is in Stand-by mode and the final stage generators
are off.
When V
pin5
between +V
S
-2.5V and +V
S
-6V the final stage current generators are switched on and
the amplifier is in mute mode.
When V
pin5
is lower than +V
S
-6V the amplifier is play mode.
Figure 3.
t
OFF
STDBY
MUTE
MUTE
MUTE
MUTE
PLAY STDBY PLAY OFF
STDBY
20
+V
S
(V)
-20
-V
S
V
IN
(mV)
Vpin5
(V)
V
S
V
S
-2.5
V
S-
6
V
S
-10
I
q
(mA)
0
VOUT
(V)
D94AU086