Datasheet
Electrical characteristics TD350E
6/18 DocID018539 Rev 3
4 Electrical characteristics
T
A
= -20 to 125 °C, VH = 16 V, VL = -10 V (unless otherwise specified).
Table 5. Electrical characteristics
Symbol Parameter Test condition Min. Typ. Max. Unit
Input
V
ton
IN turn-on threshold voltage 0.8 1.0 V
V
toff
IN turn-off threshold voltage 4.0 4.2 V
t
onmin
Minimum pulse width 100 135 220 ns
I
inp
IN input current 1 A
Voltage reference
(1)
V
ref
Voltage reference
T = 25 °C
T
min
< T < T
max
4.85
4.77
5.00 5.15
5.22
V
V
I
ref
Maximum output current 10 mA
Desaturation protection
V
des
Desaturation threshold 6.5 7.2 7.9 V
I
des
Source current 250 A
Fault output
t
fault
Delay for fault detection 500 ns
V
FL
FAULT low voltage I
FLsink
= 10 mA 1 V
Clamp
V
tclamp
CLAMP pin voltage threshold 2.0 V
V
CL
Clamp low voltage
T = 25 °C; I
CLsink
= 500 mA
T
min
< T < T
max
; I
CLsink
= 500 mA
VL + 2.5
VL + 3.0
V
V
Off delay
V
tdel
Voltage threshold 2.35 2.50 2.65 V
R
del
Discharge resistor I = 1 mA 500
Off levels
I
blvoff
LVOFF peak input current (sink) LVOFF = 12 V 120 200 A
V
iolv
Offset voltage LVOFF = 12 V -0.3 -0.15 0 V
Outputs
V
OL1
Output low voltage I
osink
= 20 mA VL + 0.35 V
V
OL2
Output low voltage
T = 25 °C, I
osink
= 200 mA
T
min
< T < T
max
,
I
osink
= 200 mA
VL +1.0
VL +1.5
V
V