Datasheet

STWD100 Package marking information
Doc ID 14134 Rev 7 23/25
8 Package marking information
Table 9. Device versions with marking descriptions
Part number
Watchdog
timing period
Output configuration Topside marking
Bottomside
marking
(1)
t
wd
t
pw
STWD100NPxxxx 3.4 ms 3.4 ms Open drain WNP PYWW
STWD100NWxxxx 6.3 ms 210 ms Open drain WNW PYWW
STWD100NXxxxx 102 ms 210 ms Open drain WNX PYWW
STWD100NYxxxx 1.6 s 210 ms Open drain WNY PYWW
STWD100PWxxxx 6.3 ms 210 ms Push-pull WPW PYWW
STWD100PXxxxx 102 ms 210 ms Push-pull WPX PYWW
STWD100PYxxxx 1.6 s 210 ms Push-pull WPY PYWW
1. Description: P = assembly plant code, Y = assembly year (0 to 9), WW = assembly work week (01 to 52).