Datasheet

DC and AC parameters STWD100
16/25 Doc ID 14134 Rev 7
5 DC and AC parameters
This section summarizes the operating measurement conditions, and the DC and AC
characteristics of the device. The parameters in Table 5 that follows, are derived from tests
performed under the measurement conditions summarized in Table 4. Designers should
check that the operating conditions in their circuit match the operating conditions when
relying on the quoted parameters.
Table 4. Operating and AC measurement conditions
Parameter Value Unit
V
CC
supply voltage 2.7 to 5.5 V
Ambient operating temperature (T
A
) –40 to 125 °C
Input rise and fall times
5ns
Input pulse voltages 0.2 to 0.8 V
CC
V
Input and output timing ref. voltages 0.3 to 0.7 V
CC
V