Datasheet

DocID13236 Rev 9 15/28
STVM100 DC and AC parameters
27
5 DC and AC parameters
This section summarizes the operating measurement conditions, and the dc and ac
characteristics of the device. The parameters in the DC and AC characteristics tables that
follow, are derived from tests performed under the measurement conditions summarized in
Table 5. Designers should check that the operating conditions in their circuit match the
operating conditions when relying on the quoted parameters.
Table 5. Operating and AC measurement conditions
Parameter Conditions Unit
V
DD
supply voltage 2.25 to 3.6 V
V
DD
EEPROM programming supply voltage 2.25 to 3.6 V
AV
DD
reference voltage 4.5 to 20 V
Ambient operating temperature (T
A
) –40 to 85 °C
Table 6. Capacitances
Symbol Parameter
(1)(2)
1. Effective capacitance measured with power supply at 3 V. Sampled only, not 100% tested.
2. At 25 °C, f = 1 MHz.
Min Max Unit
C
b
Bus capacitive load 400 pF
C
SDA
Capacitance on SDA 10 pF
C
S
Capacitance on SCL
WP = 0 10 pF
WP = 1 22 pF