Datasheet
STTS751 register summary STTS751
18/36 Doc ID 16483 Rev 5
Tres1:Tres0 [bits 3 and 2]
These bits select one of the four programmable resolutions for temperature data on the
STTS751 providing resolutions down to 0.0625 °C/LSB. The default resolution is 10 bits,
0.25 °C/LSB.
RFU [bits 1 and 0] Not used - reserved.
4.7 Conversion rate register
The STTS751 conversion rate register is read/write and controls the number of times the
temperature value will be updated each second.
The upper four bits of the register are reserved and default to 0 on power-up. The lower four
bits control the conversion rate as shown in the table below. The power-up default is 1
conversion per second. The current draw is proportional to the conversion rate, and goes up
at higher rates.
Table 16. Conversion resolution
Tres1:Tres0 Temperature resolution LSB step size (°C)
00 10 bits (default) 0.25
01 11 bits 0.125
11 12 bits 0.0625
10 9 bits 0.5
Table 17. Conversion rate register
ADDR
(hex)
R/W Register b7 b6 b5 b4 b3 b2 b1 b0
Power-up
default (hex)
04 R/W Conversion rate 0 0 0 0 CONV[3:0] 04 (1/sec)