Datasheet

Characteristics STTH8L06
2/11 Doc ID 8373 Rev 6
1 Characteristics
To evaluate the conduction losses use the following equation: P = 0.89 x I
F(AV)
+ 0.022 I
F
2
(RMS)
Table 2. Absolute ratings (limiting values)
Symbol Parameter Value Unit
V
RRM
Repetitive peak reverse voltage 600 V
I
F(RMS)
Forward rms current
TO-220AC / TO-220FPAC / D
2
PAK 30
A
TO-220AC Ins. 24
I
F(AV)
Average forward current
δ = 0.5
TO-220AC / D
2
PAK T
c
= 150 °C
8ATO-220FPAC T
c
= 125 °C
TO-220AC Ins. T
c
= 135 °C
I
FSM
Surge non repetitive forward current t
p
= 10 ms sinusoidal 120 A
T
stg
Storage temperature range -65 to 175 °C
T
j
Operating junction temperature range -40 to 175 °C
Table 3. Thermal resistance
Symbol Parameter Value (max) Unit
R
th(j-c)
Junction to case
TO-220AC / D
2
PA K 2. 5
°C/WTO-220FPAC 5
TO-220AC Ins. 4
Table 4. Static electrical characteristics
Symbol Parameter Test conditions Min. Typ. Max. Unit
I
R
Reverse leakage current
T
j
= 25 °C
V
R
= V
RRM
8
µA
T
j
= 150 °C 16 200
V
F
Forward voltage drop
T
j
= 25 °C
I
F
= 8 A
1.3
V
T
j
= 150 °C 0.85 1.05
Table 5. Dynamic characteristics
Symbol Parameter Test conditions Min. Typ. Max. Unit
t
rr
Reverse
recovery time
T
j
= 25 °C I
F
= 1 A, dI
F
/dt = -50 A/µs V
R
= 30 V 75 105 ns
I
RM
Reverse
recovery current
T
j
= 125 °C
I
F
= 8 A, dI
F
/dt = 100 A/µs,
V
R
= 400 V
7.2 10 A
t
fr
Forward
recovery time
T
j
= 25°C
I
F
= 8 A, dI
F
/dt = 100 A/µs
V
FR
= 1.1 x V
Fmax
150 ns
V
FP
Forward
recovery voltage
I
F
= 8 A, dI
F
/dt = 100 A/µs
6V