Datasheet

Application information STSMIA832
12/25 Doc ID 12174 Rev 5
X = Don’t care
Figure 10. Bypass decoupling capacitors
Table 3. Synchronization codes as per SMIA specifications
Input Output
Function
EN SYNC_SEL D+ D- STRB+ STRB- V-SYNC H-SYNC D1-D8 CLK
LXXXXXLLLLSMIA disabled
HHSOF (FF
H
00
H
00
H
02
H
)H H
See Figure 14
Start of Frame
HHEOF(FF
H
00
H
00
H
03
H
) L L End of Frame
HHSOL(FF
H
00
H
00
H
00
H
)
No
Change
H Start of Line
HHEOL(FF
H
00
H
00
H
01
H
)
No
Change
L End of Line
HLXXXXLL
D+, D-
data in
parallel
mode
See
Figure 13
Disabled Sync
(D1-D8 will get
out data, including
Sync Code)
Table 4. Class function table (CSI classification)
CLASS
Data transfer capacity
(sustained data rate)
Signaling method CLASS_SEL
Class 0 < 208 Mbps Data/Clock GND
Class 1 208-416 Mbps Data/Strobe V
L
Class 2 416-650 Mbps Data/Strobe V
L