Electrical ratings STP24DP05
6/27 Doc ID 14714 Rev 5
2.3 Recommended operating conditions
Table 6. Recommended operating conditions
Symbol Parameter Test conditions Min. Typ. Max. Unit
V
DD
Supply voltage 3.0 5.5 V
V
O
Output voltage 20 V
I
O
Output current OUTn 5 80 mA
I
OH
Output current Serial-OUT +10 mA
I
OL
Output current Serial-OUT -10 mA
V
IH
Input voltage 0.7 V
DD
V
DD
+0.3 V
V
IL
Input voltage -0.3 0.3 V
DD
V
t
wLAT
LE pulse width
V
DD
= 3.0 V to 5.0 V
15 ns
t
wCLK
CLK pulse width 15 ns
t
wEN
OE pulse width 150 ns
t
SETUP(D)
Setup time for DATA 15 ns
t
HOLD(D)
Hold time for DATA 5 ns
t
SETUP(L)
Setup time for LATCH 10 ns
f
CLK
Clock frequency Cascade operation
(1)
1. If the device is connected in cascade, it may not be possible to achieve the maximum data transfer. Please
consider the timings carefully.
25 MHz