Datasheet

3/9
STP16NF06L/FP
SWITCHING ON
SWITCHING OFF
SOURCE DRAIN DIODE
(*)
Pulsed: Pulse duration = 300 µs, duty cycle 1.5 %.
(
•)Pulse width limited by safe operating area.
Symbol Parameter Test Conditions Min. Typ. Max. Unit
t
d(on)
t
r
Turn-on Delay Time
Rise Time
V
DD
= 30 V I
D
= 8 A
R
G
=4.7 V
GS
= 4.5 V
(Resistive Load, Figure 3)
10
37
ns
ns
Q
g
Q
gs
Q
gd
Total Gate Charge
Gate-Source Charge
Gate-Drain Charge
V
DD
= 48 V I
D
= 16 A V
GS
= 5V
7.3
2.1
3.1
10 nC
nC
nC
Symbol Parameter Test Conditions Min. Typ. Max. Unit
t
d(off)
t
f
Turn-off Delay Time
Fall Time
V
DD
= 30 V I
D
= 8 A
R
G
=4.7Ω, V
GS
= 4.5 V
(Resistive Load, Figure 3)
20
12.5
ns
ns
Symbol Parameter Test Conditions Min. Typ. Max. Unit
I
SD
I
SDM
()
Source-drain Current
Source-drain Current (pulsed)
16
64
A
A
V
SD
(*)
Forward On Voltage
I
SD
= 16 A V
GS
= 0
1.3 V
t
rr
Q
rr
I
RRM
Reverse Recovery Time
Reverse Recovery Charge
Reverse Recovery Current
I
SD
= 16 A di/dt = 100A/µs
V
DD
= 16 V T
j
= 150°C
(see test circuit, Figure 5)
50
67.5
2.7
ns
nC
A
ELECTRICAL CHARACTERISTICS (continued)