Datasheet
Electrical characteristics STP16DPPS05
8/34 Doc ID 15817 Rev 2
V
DD
= 3.3 V to 5 V, T
A
= 25 °C, unless otherwise specified.
Table 8. Switching characteristics
Symbol Parameter Test conditions Min Typ Max Unit
t
PLH1
Propagation delay time,
CLK-OUTn
, LE/DM1 = H,
OE/DM2 = L
V
IH
= V
DD
V
IL
= GND C
L
= 10 pF
I
O
= 20 mA V
L
= 3.0 V
R
EXT
= 1 KΩ R
L
= 60 Ω
V
DD
= 3.3 V 53.5 86.5
ns
V
DD
= 5 V 32 46.5
t
PLH2
Propagation delay time,
LE/DM1-OUTn
,
OE/DM2 = L
V
DD
= 3.3 V 48 75.5
ns
V
DD
= 5 V 30 43
t
PLH3
Propagation delay time,
OE/DM2
-OUTn, LE = H
V
DD
= 3.3 V 71.5 118
ns
V
DD
= 5 V 43 62
t
PLH
Propagation delay time,
CLK-SDO
V
DD
= 3.3 V 15 21 31
ns
V
DD
= 5 V 11 15 21
t
PHL1
Propagation delay time,
CLK-OUTn, LE/DM1 = H,
OE/DM2
= L
V
DD
= 3.3 V 27.5 39
ns
V
DD
= 5 V 22 30.5
t
PHL2
Propagation delay time,
LE/DM1-OUTn,
OE/DM2
= L
V
DD
= 3.3 V 11.5 17.5
ns
V
DD
= 5 V 8 11.5
t
PHL3
Propagation delay time,
OE/DM2-OUTn,
LE/DM1 = H
V
DD
= 3.3 V 24 33.5
ns
V
DD
= 5 V 21 28.5
t
PHL
Propagation delay time,
CLK-SDO
V
DD
= 3.3 V 17.5 24 36
ns
V
DD
= 5 V 12.5 17 25
t
ON
Output rise time
10~90% of voltage
waveform
V
DD
= 3.3 V 29 54
ns
V
DD
= 5 V 10 17
t
OFF
Output fall time
90~10% of voltage
waveform
V
DD
= 3.3 V 4.5 6
ns
V
DD
= 5 V 3.5 5
t
r
CLK rise time
(1)
5000 ns
t
f
CLK fall time
(1)
5000 ns
1. In order to achieve high cascade data transfer, please consider tr/tf timings carefully.