Datasheet
STP16DP05 Electrical ratings
Doc ID 13093 Rev 6 5/31
2.3 Recommended operating conditions
Table 6. Recommended operating conditions
Symbol Parameter Test conditions Min. Typ. Max. Unit
V
DD
Supply voltage 3.0 - 5.5 V
V
O
Output voltage - 20 V
I
O
Output current OUTn 5 - 100 mA
I
OH
Output current SERIAL-OUT - +1 mA
I
OL
Output current SERIAL-OUT - -1 mA
V
IH
Input voltage 0.7V
DD
-V
DD
+0.3 V
V
IL
Input voltage -0.3 - 0.3V
DD
V
t
wLAT
LE\DM1 pulse width
V
DD
= 3.0 V to 5.0 V
6- ns
t
wCLK
CLK pulse width 8 - ns
t
wEN
OE\DM2 pulse width 100 - ns
t
SETUP(D)
Setup time for DATA 10 - ns
t
HOLD(D)
Hold time for DATA 5 - ns
t
SETUP(L)
Setup time for LATCH 10 - ns
f
CLK
Clock frequency Cascade operation
(1)
1. If the device is connected in cascade, it may not be possible achieve the maximum data transfer.
Please consider the timings carefully.
-30MHz