Datasheet

STP16DP05 Detection mode functionality
Doc ID 13093 Rev 6 21/31
Figure 20. Error detection sequence
LE and OE Key
Sequence
necessary to Enter
in EDM
16 CLK pulse are required to
load the data setting 1 into
shift register
The LE pulse
latch the data
loaded during the
previous state
During the error
detection are
necessary at least
2 CLK signal plus
oneat the end
Every CLK pulse shows the results of
single Output results:Out15;14; 13 etc. etc
After OE signal turn High the
SDO pin show the results of
Error Detection (Open or
Short in this case)
The OE Pulse put
the device from
EDM to Normal
Mode
LE and OE Key
Sequence
necessary to Enter
in EDM
16 CLK pulse are required to
load the data setting 1 into
shift register
The LE pulse
latch the data
loaded during the
previous state
During the error
detection are
necessary at least
2 CLK signal plus
oneat the end
Every CLK pulse shows the results of
single Output results:Out15;14; 13 etc. etc
After OE signal turn High the
SDO pin show the results of
Error Detection (Open or
Short in this case)
The OE Pulse put
the device from
EDM to Normal
Mode