Datasheet
STP16DP05 Detection mode functionality
Doc ID 13093 Rev 6 19/31
7.3 Phase three: “resuming to normal mode”
The sequence for re-entering in normal mode is showed in the following table and diagram:
Note: For proper device operation the “Entering in detection” sequence must be follow by a
“resume mode” sequence, it is not possible to insert consecutive equal sequence.
7.4 Error detection conditions
V
DD
= 3.3 to 5 V temperature range -40 to 125 °C
Note: Where: I
O
= the output current programmed by the R
EXT
, I
ODEC
= the detected output
current in detection mode
Figure 18. Resuming to normal mode timing diagram
CLK1°2°3°4°5°
OE/DM2
HLHHH
LE/DM1 LLLLL
Table 13. Detection conditions
SW-1 or
SW-3b
Open line or output
short to GND detected
==> I
ODEC
≤ 0.5 x I
O
No error detected
==> I
ODEC
≥ 0.5 x I
O
SW-2 or
SW-3a
Short on LED or short
to V-LED detected
==> V
O
≥ 2.4 V
No error detected
==> V
O
≤ 2.2 V