Datasheet
STP16CPP05 Electrical ratings
Doc ID 15379 Rev 2 5/28
2.3 Recommended operating conditions
Table 6. Recommended operating conditions at 25 °C
Symbol Parameter Test conditions Min Typ Max Unit
V
DD
Supply voltage 3.0 5.5 V
V
O
Output voltage 20 V
I
O
Output current OUTn 3 40 mA
I
OH
Output current SERIAL-OUT +1 mA
I
OL
Output current SERIAL-OUT -1 mA
V
IH
Input voltage 0.7 V
DD
V
DD
+0.3 V
V
IL
Input voltage -0.3 0.3 V
DD
V
t
wLAT
LE pulse width
V
DD
= 3.3 V to 5.0 V
20 ns
t
wCLK
CLK pulse width 16 ns
t
wEN
OE pulse width 70 ns
t
SETUP(D)
Setup time for DATA 5 ns
t
HOLD(D)
Hold time for DATA 5 ns
t
SETUP(L)
Setup time for LATCH 15 ns
f
CLK
Clock frequency Cascade operation
(1)
1. If the device is connected in cascade, it may not be possible achieve the maximum data transfer. Please
considered the timings carefully.
30 MHz