Datasheet
Electrical ratings STP16CPC26
4/26 Doc ID 18469 Rev 4
2 Electrical ratings
2.1 Absolute maximum ratings
Stressing the device above the rating listed in the “absolute maximum ratings” table may
cause permanent damage to the device. These are stress ratings only and operation of the
device at these or any other conditions above those indicated in the operating sections of
this specification is not implied. Exposure to absolute maximum rating conditions for
extended periods may affect device reliability.
2.2 Thermal data
Table 3. Absolute maximum ratings
Symbol Parameter Value Unit
V
DD
Supply voltage 0 to 7 V
V
O
Output voltage -0.5 to 20 V
I
O
Output current 90 mA
V
I
Input voltage -0.4 to V
DD
+0.4 V
I
GND
GND terminal current 1600 mA
ESD
Electrostatic discharge protection HBM human
body model
±2 kV
f
CLK
Clock frequency 30 MHz
Table 4. Thermal data
Symbol Parameter Value Unit
T
A
Operating free-air temperature range -40 to +125
°CT
OPR
Operating temperature range -40 to +150
T
STG
Storage temperature range -55 to +150
R
thJA
Thermal resistance junction-case
(1)
1. According with JEDEC standard 51-7B.
SO-24 60
°C/W
TSSOP24 85
TSSOP24
(2)
2. The exposed pad should be soldered directly to the PCB to realize the thermal benefits.
37.5
QSOP24 72