Datasheet

Maximum rating STP08DP05
6/34 DocID13405 Rev 5
3.3 Recommended operating conditions
Table 6. Recommended operating conditions
Symbol Parameter Test conditions Min. Typ. Max. Unit
V
DD
Supply voltage 3.0 - 5.5 V
V
O
Output voltage - 20 V
I
O
Output current OUTn 5 - 100 mA
I
OH
Output current SERIAL-OUT - +1 mA
I
OL
Output current SERIAL-OUT - -1 mA
V
IH
Input voltage 0.7V
DD
-V
DD
+0.3 V
V
IL
Input voltage -0.3 - 0.3V
DD
V
t
wLAT
LE/DM1 pulse width
V
DD
= 3.0 to 5.0V
20 - ns
t
wCLK
CLK pulse width 20 - ns
t
wEN
OE/DM2 pulse width 200 - ns
t
SETUP(D)
Setup time for DATA 7 - ns
t
HOLD(D)
Hold time for DATA 4 - ns
t
SETUP(L)
Setup time for LATCH 15 - ns
f
CLK
Clock frequency Cascade operation
(1)
1. If the device is connected in cascade, it may not be possible achieve the maximum data transfer. Please
consider the timings carefully.
-30MHz