Datasheet

Maximum rating STP04CM05
6/23 Doc ID 14191 Rev 5
3.2 Recommended operating conditions
Table 5. Recommended operating conditions
Symbol Parameter Test conditions Min. Typ. Max. Unit
V
DD
Supply voltage 3.3 5.0 5.5 V
V
O
Output voltage 19 V
I
O
Output current OUTn V
DD
= 5 V 80 400 mA
I
OH
Output current Serial-OUT +1 mA
I
OL
Output current Serial-OUT -1 mA
V
IH
Input voltage 0.7V
DD
V
DD
+0.3 V
V
IL
Input voltage -0.3 0.3V
DD
V
t
wEN
OE pulse width
V
DD
= 5 V,
I
O
= 350 mA
80 50
ns
V
DD
= 3.3 V,
I
O
= 350 mA
250 150
t
wLAT
LE pulse width
V
DD
= 3.0 to 3.6 V
84 ns
t
wCLK
CLK pulse width 8.5 7.5 ns
t
SETUP(D)
Setup time for DATA 8.5 7.5 ns
t
HOLD(D)
Hold time for DATA 8.5 7.5 ns
t
SETUP(L)
Setup time for LATCH 8.5 7.0 ns
t
HOLD(E)
Hold time for ENABLE 8.5 7.0 ns
f
CLK
Clock frequency Cascade operation
(1)
1. If multiple devices are cascaded, it may not be possible achieve the maximum data transfer. Please
consider the timing conditions carefully.
30 MHz
T
OPR
Operating temperature
range
-40 +125 °C