Datasheet

STOTG04E Electrical characteristics
9/26
NOTE 1: Parameter applies to the OE_TP_INT/, DAT_VP, and SE0_VM signals
NOTE 2: Not tested in production; characterization only
NOTE 3: Requirements defined by the I2C-Bus Specification, version 2.1
t
IICF
Fall time of both SDA and SCL
signals
300 ns
t
SU_STA
Setup time for a repeated START
condition
4.7 µs
t
HD_STA
Hold time for the START and
repeated START conditions
4.0 µs
t
SU_DAT
Data setup time 250 ns
t
HD_DAT
Data hold time 0 µs
t
SU_STO
Setup time for the STOP
condition
4.0 µs
t
BUF
Bus free time between a STOP
and START condition
4.7 µs
Symbol Parameter Test Conditions Min. Typ. Max. Unit