Datasheet

Electrical characteristics STM8S207xx, STM8S208xx
60/103 Doc ID 14733 Rev 12
Total current consumption in active halt mode
Table 24. Total current consumption in active halt mode at V
DD
= 5 V, T
A
-40 to 85° C
Symbol Parameter
Conditions
Typ Max
(1)
Unit
Main voltage
regulator
(MVR)
(2)
Flash mode
(3)
Clock source
I
DD(AH)
Supply current in
active halt mode
On
Operating mode
HSE crystal oscillator
(16 MHz)
1000
µA
LSI RC oscillator
(128 kHz)
200 260
Powerdown mode
HSE crystal oscillator
(16 MHz)
940
LSI RC oscillator
(128 kHz)
140
Off
Operating mode
LSI RC oscillator
128 kHz)
68
Powerdown mode 11 45
1. Data based on characterization results, not tested in production.
2. Configured by the REGAH bit in the CLK_ICKR register.
3. Configured by the AHALT bit in the FLASH_CR1 register.
Table 25. Total current consumption in active halt mode at V
DD
= 3.3 V
Symbol Parameter
Conditions
Typ
(1)
Unit
Main voltage
regulator
(MVR)
(2)
Flash mode
(3)
Clock source
I
DD(AH)
Supply current in
active halt mode
On
Operating mode
HSE crystal osc. (16 MHz) 600
µA
LSI RC osc. (128 kHz) 200
Powerdown mode
HSE crystal osc. (16 MHz) 540
LSI RC osc. (128 kHz) 140
Off
Operating mode
LSI RC osc. (128 kHz)
66
Powerdown mode 9
1. Data based on characterization results, not tested in production.
2. Configured by the REGAH bit in the CLK_ICKR register.
3. Configured by the AHALT bit in the FLASH_CR1 register.