Datasheet

STM8S207xx, STM8S208xx Electrical characteristics
Doc ID 14733 Rev 12 51/103
10 Electrical characteristics
10.1 Parameter conditions
Unless otherwise specified, all voltages are referred to V
SS
.
10.1.1 Minimum and maximum values
Unless otherwise specified the minimum and maximum values are guaranteed in the worst
conditions of ambient temperature, supply voltage and frequencies by tests in production on
100 % of the devices with an ambient temperature at T
A
= 25 °C and T
A
= T
Amax
(given by
the selected temperature range).
Data based on characterization results, design simulation and/or technology characteristics
are indicated in the table footnotes and are not tested in production. Based on
characterization, the minimum and maximum values refer to sample tests and represent the
mean value plus or minus three times the standard deviation (mean ± 3
Σ).
10.1.2 Typical values
Unless otherwise specified, typical data are based on T
A
= 25 °C, V
DD
= 5 V. They are given
only as design guidelines and are not tested.
Typical ADC accuracy values are determined by characterization of a batch of samples from
a standard diffusion lot over the full temperature range, where 95% of the devices have an
error less than or equal to the value indicated
(mean ± 2 Σ).
10.1.3 Typical curves
Unless otherwise specified, all typical curves are given only as design guidelines and are
not tested.
10.1.4 Typical current consumption
For typical current consumption measurements, V
DD
, V
DDIO
and V
DDA
are connected
together in the configuration shown in
Figure 9.
Figure 9. Supply current measurement conditions
V
DD
V
DDA
V
DDIO
V
SS
V
SSA
V
SSIO
A
5 V or 3.3 V