Datasheet

(1)
Data based on characterization results, not tested in production
Static latch-up10.3.11.6
Two complementary static tests are required on 10 parts to assess the latch-up performance:
A supply overvoltage (applied to each power supply pin)
A current injection (applied to each input, output and configurable I/O pin) are performed
on each sample.
This test conforms to the EIA/JESD 78 IC latch-up standard. For more details, refer to the
application note AN1181.
Table 51: Electrical sensitivities
Class
(1)
ConditionsParameterSymbol
AT
A
= 25 °C
Static latch-up classLU
AT
A
= 85 °C
AT
A
= 125 °C
(1)
Class description: A Class is an STMicroelectronics internal specification. All its limits
are higher than the JEDEC specifications, that means when a device belongs to class A it
exceeds the JEDEC standard. B class strictly covers all the JEDEC criteria (international
standard).
93/117DocID15441 Rev 9
Electrical characteristicsSTM8S103K3 STM8S103F3 STM8S103F2