Datasheet
Total current consumption in halt mode10.3.2.4
Table 27: Total current consumption in halt mode at V
DD
= 5 V
Unit
Max at
125 °C
(1)
Max at
85 °C
(1)
TypConditionsParameterSymbol
μA
1057563
Flash in operating mode, HSI
clock after wakeup
Supply current in
halt mode
I
DD(H)
55206.0
Flash in power-down mode, HSI
clock after wakeup
(1)
Data based on characterization results, not tested in production
Table 28: Total current consumption in halt mode at V
DD
= 3.3 V
Unit
Max at
125 °C
(1)
Max at
85 °C
(1)
TypConditionsParameterSymbol
μA
1007560
Flash in operating mode, HSI
clock after wakeup
Supply current in
halt mode
I
DD(H)
30174.5
Flash in power-down mode, HSI
clock after wakeup
(1)
Data based on characterization results, not tested in production
Low power mode wakeup times10.3.2.5
Table 29: Wakeup times
Unit
Max
(1)
TypConditionsParameterSymbol
μs
See
note
(2)
-0 to 16 MHz
Wakeup time from
wait mode to run
t
WU(WFI)
0.56f
CPU
= f
MASTER
= 16 MHzmode
(3)
2
(6)
1
(6)
HSI
(after
Flash in operating
mode
(5)
MVR voltage
regulator
on
(4)
Wakeup time active
halt mode to run
mode
(3)
t
WU(AH)
wakeup)
-3
(6)
HSI
(after
Flash in
power-down
MVR voltage
regulator
Wakeup time active
halt mode to run
wakeup)mode
(5)
on
(4)
mode
(3)
DocID15441 Rev 960/117