Datasheet

Electrical parameters STM8L151xx, STM8L152xx
76/131 DocID15962 Rev 13
I
DD(AH)
Supply current in
Active-halt mode
LSE external
clock
(32.768 kHz)
(6)
LCD OFF
(7)
T
A
= -40 °C to 25 °C
0.5 1.2
A
T
A
= 55 °C 0.62 1.4
T
A
= 85 °C 0.88 2.1
T
A
= 105 °C 2.1 4.85
T
A
= 125 °C 4.8 11
LCD ON
(static duty/
external
V
LCD
)
(3)
T
A
= -40 °C to 25 °C
0.85 1.9
T
A
= 55 °C 0.95 2.2
T
A
= 85 °C 1.3 3.2
T
A
= 105 °C 2.3 5.3
T
A
= 125 °C 5.0 12
LCD ON
(1/4 duty/
external
V
LCD
)
(4)
T
A
= -40 °C to 25 °C
1.5 2.5
T
A
= 55 °C 1.6 3.8
T
A
= 85 °C 1.8 4.2
T
A
= 105 °C 2.9 7.0
T
A
= 125 °C 5.7 14
LCD ON
(1/4 duty/
internal
V
LCD
)
(5)
T
A
= -40 °C to 25 °C
3.4 7.6
T
A
= 55 °C 3.7 8.3
T
A
= 85 °C 3.9 9.2
T
A
= 105 °C 5.0 14.5
T
A
= 125 °C 6.3 15.2
I
DD(WUFAH)
Supply current during
wakeup time from
Active-halt mode
(using HSI)
-2.4-mA
t
WU_HSI(AH)
(8)(9)
Wakeup time from
Active-halt mode to
Run mode (using HSI)
-4.77s
t
WU_LSI(AH)
(8)
(9)
Wakeup time from
Active-halt mode to
Run mode (using LSI)
- 150 - s
1. No floating I/O, unless otherwise specified.
2. RTC enabled. Clock source = LSI
3. RTC enabled, LCD enabled with external V
LCD
= 3 V, static duty, division ratio = 256, all pixels active, no LCD connected.
4. RTC enabled, LCD enabled with external V
LCD
, 1/4 duty, 1/3 bias, division ratio = 64, all pixels active, no LCD connected.
5. LCD enabled with internal LCD booster V
LCD
= 3 V , 1/4 duty, 1/3 bias, division ratio = 64, all pixels active, no LCD
connected.
6. Oscillator bypassed (LSEBYP = 1 in CLK_ECKCR). When configured for extenal crystal, the LSE consumption
(I
DD LSE
) must be added. Refer to Table 32.
7. RTC enabled. Clock source = LSE.
8. Wakeup time until start of interrupt vector fetch.
The first word of interrupt routine is fetched 4 CPU cycles after t
WU
.
9. ULP=0 or ULP=1 and FWU=1 in the PWR_CSR2 register.
Table 24. Total current consumption and timing in Active-halt mode at V
DD
= 1.65 V to 3.6 V
Symbol Parameter
Conditions
(1)
Typ Max Unit