STM8L151x2, STM8L151x3 Electrical parameters
Doc ID 018780 Rev 4 95/112
Electrostatic discharge (ESD)
Electrostatic discharges (a positive then a negative pulse separated by 1 second) are
applied to the pins of each sample according to each pin combination. The sample size
depends on the number of supply pins in the device (3 parts*(n+1) supply pin). Two models
can be simulated: human body model and charge device model. This test conforms to the
JESD22-A114A/A115A standard.
Static latch-up
LU: 3 complementary static tests are required on 6 parts to assess the latch-up
performance. A supply overvoltage (applied to each power supply pin) and a current
injection (applied to each input, output and configurable I/O pin) are performed on each
sample. This test conforms to the EIA/JESD 78 IC latch-up standard. For more details,
refer to the application note AN1181.
Table 52. ESD absolute maximum ratings
Symbol Ratings Conditions
Maximum
value
(1)
1. Data based on characterization results, not tested in production.
Unit
V
ESD(HBM)
Electrostatic discharge voltage
(human body model)
T
A
= +25 °C
2000
V
V
ESD(CDM)
Electrostatic discharge voltage
(charge device model)
500
Table 53. Electrical sensitivities
Symbol Parameter Class
LU Static latch-up class II