5 DC and AC parameters
This section summarizes the operating measurement conditions, and the DC and AC
characteristics of the device. The parameters in Table 6: DC and AC characteristic, are
derived from tests performed under the measurement conditions summarized in Table 5:
Operating and AC measurement conditions. Designers should check that the operating
conditions in their circuit match the operating conditions when relying on the quoted
parameters.
Figure 24. AC testing input/output waveforms
Figure 25. MR
timing waveform
1. RST for STM6322/6821/6825.
Table 5. Operating and AC measurement conditions
Parameter STM6xxx Unit
V
CC
supply voltage 1.0 to 5.5 V
Ambient operating temperature (T
A
) –40 to 85 °C
Input rise and fall times
5ns
Input pulse voltages 0.2 to 0.8 V
CC
V
Input and output timing ref. voltages 0.3 to 0.7 V
CC
V
!)6
6
##
6
##
6
##
6
##
!)6
234

-2
T
-,2,
T
REC
T
-,-(