Datasheet

Table Of Contents
DC and AC parameters STM6717/6718/6719/6720/STM6777/6778/6779/6780
18/30 Doc ID 11469 Rev 8
5 DC and AC parameters
This section summarizes the operating measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristics tables that
follow, are derived from tests performed under the measurement conditions summarized in
Table 5: Operating and AC measurement conditions. Designers should check that the
operating conditions in their circuit match the operating conditions when relying on the
quoted parameters.
Figure 25. AC testing input/output waveforms
Figure 26. MR
timing waveform (STM6717/18/19/20)
Figure 27. MR
timing waveform (STM6777/78/79/80)
1. By connecting a certain capacitor between the MRC pin and V
SS
, the RST can be delayed from 6 µs or
more (t
MLMH
, see Table 7 on page 21).
Table 5. Operating and AC measurement conditions
Parameter STM67xx Unit
V
CC
supply voltage 0.8 to 5.5 V
Ambient operating temperature (T
A
) –40 to 85 °C
Input rise and fall times 5ns
Input pulse voltages 0.2 to 0.8V
CC
V
Input and output timing ref. voltages 0.3 to 0.7V
CC
V
AI02568
0.8V
CC
0.2V
CC
0.7V
CC
0.3V
CC
AI10423a
RST
MR
t
MLRL
t
rec
t
MLMH
AI10424c
RST
MR
t
rec
t
MLMH
(1)
t