Datasheet

This is information on a product in full production.
June 2012 Doc ID 15453 Rev 11 1/52
1
STM6600, STM6601
Smart push-button on/off controller with Smart Reset™ and
power-on lockout
Datasheet production data
Features
Operating voltage 1.6 V to 5.5 V
Low standby current of 0.6 µA
Adjustable Smart Reset
assertion delay time
driven by external C
SRD
Power-up duration determined primarily by
push-button press (STM6600) or by fixed time
period, t
ON_BLANK
(STM6601)
Debounced PB and SR inputs
PB and SR ESD inputs withstand voltage up to
±15 kV (air discharge) ±8 kV (contact
discharge)
Active high or active low enable output option
(EN
or EN) provides control of MOSFET,
DC-DC converter, regulator, etc.
Secure startup, interrupt, Smart Reset
or
power-down driven by push-button
Precise 1.5 V voltage reference with 1%
accuracy
Industrial operating temperature –40 to +85 °C
Available in TDFN12 2 x 3 mm package
Applications
Portable devices
Termin
als
A
udio and video players
Cell phones and smart phones
PDAs, palmtops, organizers
TDFN12
Table 1. Device summary
Device RST C
SRD
PB / SR EN or EN INT Startup process
STM6600 open drain
(1)
✓✓push-pull open drain
(1)
PB must be held low until the
PS
HOLD
(2)
confirmation
STM6601 open drain
(1)
✓✓push-pull open drain
(1)
PB can be released before the
PS
HOLD
(2)
confirmation
1. External pull-up resistor needs to be connected to open drain outputs.
2. For a successful startup, the PS
HOLD
(Power Supply Hold) needs to be pulled high within specific time, t
ON_BLANK
.
www.st.com

Summary of content (52 pages)