Datasheet
STM6600, STM6601 DC and AC characteristics
Doc ID 15453 Rev 11 39/52
7 DC and AC characteristics
This section summarizes the operating measurement conditions and the DC and AC
characteristics of the device. The parameters inTable 5 that follow are derived from tests
performed under the measurement conditions summarized in Table 4. Designers should
check that the operating conditions in their circuit match the operating conditions when
relying on the quoted parameters.
Table 4. Operating and AC measurement conditions
Parameter Condition Unit
V
CC
supply voltage 1.6 to 5.5 V
Ambient operating temperature (T
A
) –40 to 85 °C
Input rise and fall times ≤
_
5ns
Table 5. DC and AC characteristics
Symbol Parameter Test condition
(1)
Min. Typ.
(2)
Max. Unit
V
CC
Supply voltage 1.6 5.5 V
I
CC
Supply current
V
CC
= 3.6 V, no load 6.0 8.0 µA
Standby mode, enable
deasserted, V
CC
= 3.6 V
0.6 1.0 µA
V
TH+
Power-on lockout voltage
(see Ta ble 10 for detailed
listing)
2.40 2.50 2.60
V
3.00 3.10 3.20
3.20 3.30 3.40
3.29 3.40 3.51
3.39 3.50 3.61
V
HYST
Threshold hysteresis (see
Table 10 for detailed listing)
200
mV
500
V
TH–
Forced power-off voltage
(see Ta ble 10 for detailed
listing)
V
TH+
– V
HYST
V
t
TH–
Undervoltage detection to
INT
delay
V
CC
≥ 2.0 V203244ms
t
ON_BLANK
Blanking period (see
Table 10 for detailed
listing)
(3)
1.4 2.2 3.0
s5.6 8.8 12.0
11.2 17.6 24.0
RST
assertion to EN (EN)
assertion delay during
power-up
V
CC
= 3.6 V 100 ns