Datasheet

DC and AC parameters STM6524
16/24 Doc ID 022335 Rev 3
7 DC and AC parameters
This section summarizes the operating measurement conditions, and the DC and AC
characteristics of the device. The parameters inTable 4: DC and AC characteristic that
follow, are derived from tests performed under the measurement conditions summarized in
Table 3: Operating and measurement conditions. Designers should check that the operating
conditions in their circuit match the operating conditions when relying on the quoted
parameters.
Table 3. Operating and measurement conditions
Symbol Parameter Value Unit
V
CC
Supply voltage 1.65 to 5.5 V
T
A
Ambient operating temperature -40 to +85 °C