Datasheet

DC and AC parameters STM6513
18/29 Doc ID 16490 Rev 2
Table 5. DC and AC characteristics
Symbol Parameter Test conditions
(1)
Min. Typ.
(2)
Max. Units
V
CC
Supply voltage range
Reset output valid - active-low 1.0 5.5 V
Reset output valid - active-high 1.2 5.5 V
I
CC
Supply current (V
CC
)
V
CC
= 3.0 V, TSR left open
(3)
35µA
V
CC
= 5.0 V, TSR left open 4 6 µA
V
OL
Reset output voltage
low
V
CC
4.5 V, sinking 3.2 mA 0.3 V
V
CC
3.3 V, sinking 2.5 mA 0.3 V
V
CC
1.0 V, sinking 0.1 mA 0.3 V
V
OH
Reset output voltage
high, RST1
V
CC
4.5 V, I
SOURCE
= 0.8 mA 0.8 V
CC
V
V
CC
2.7 V, I
SOURCE
= 0.5 mA 0.8 V
CC
V
V
CC
1.2 V, I
SOURCE
= 0.05 mA 0.8 V
CC
V
V
RST
Fixed voltage trip
point for V
CC
monitoring (refer to
Ta bl e 6 )
–40 to +85 °C V
RST
–2.5% V
RST
V
RST
+2.5% V
25 °C V
RST
–2.0% V
RST
V
RST
+2.0% V
V
HYST
Hysteresis of V
RST
L, M 0.5%
T, S, R, Z, Y, W, V 1%
V
CC
to reset delay
(4)
V
CC
falling from (V
RST
+ 100 mV)
to (V
RST
- 100 mV) at 10 mV/µs
20 µs
t
REC2
Output reset timeout
period on RST2
,
factory-programmed
Option E 140 210 280 ms
Option F 240 360 480 ms
t
REC1
User-adjustable
output reset timeout
period on RST1
Refer to Ta bl e 2 .
10 000 x
C
tREC
(µF)
15 000 x
C
tREC
(µF)
20 000 x
C
tREC
(µF)
ms