Datasheet

DocID022799 Rev 6 67/132
STM32L15xCC STM32L15xRC STM32L15xUC STM32L15xVC Electrical characteristics
111
I
DD
(Stop)
Supply current in Stop
mode (RTC disabled)
Regulator in LP mode, HSI
and HSE OFF, independent
watchdog and LSI enabled
T
A
= -40°C to 25°C 1.6 2.2
µA
Regulator in LP mode, LSI,
HSI and HSE OFF (no
independent watchdog)
T
A
= -40°C to 25°C 0.65 1
T
A
= 55°C 1.3 3
T
A
= 85°C 4.4 9
T
A
= 105°C 10.0 22
(5)
I
DD
(WU from
Stop)
Supply current during
wakeup from Stop
mode
MSI = 4.2 MHz
T
A
= -40°C to 25°C
2-
mAMSI = 1.05 MHz 1.45 -
MSI = 65 kHz
(6)
1.45 -
1. Based on characterization, not tested in production, unless otherwise specified.
2. LCD enabled with external VLCD, static duty, division ratio = 256, all pixels active, no LCD connected.
3. LCD enabled with external VLCD, 1/8 duty, 1/3 bias, division ratio = 64, all pixels active, no LCD connected.
4. Based on characterization done with a 32.768 kHz crystal (MC306-G-06Q-32.768, manufacturer JFVNY) with two 6.8 pF
loading capacitors.
5. Tested in production.
6. When MSI = 64 kHz, the RMS current is measured over the first 15 µs following the wakeup event. For the remaining part
of the wakeup period, the current corresponds the Run mode current.
Table 23. Typical and maximum current consumptions in Stop mode (continued)
Symbol Parameter Conditions Typ Max
(1)
Unit
Table 24. Typical and maximum current consumptions in Standby mode
Symbol Parameter Conditions Typ Max
(1)
Unit
I
DD
(Standby
with
RTC)
Supply current in Standby
mode with RTC enabled
RTC clocked by LSI (no
independent watchdog)
T
A
= -40 °C to 25 °C 1.3 1.9
µA
T
A
= 55 °C 1.44 2.2
T
A
= 85 °C 1.90 4
T
A
= 105 °C 3.05 8.3
(2)
RTC clocked by LSE
external quartz(no
independent
watchdog)
(3)
T
A
= -40 °C to 25 °C 1.7 -
T
A
= 55 °C 1.84 -
T
A
= 85 °C 2.33 -
T
A
= 105 °C 3.59 -
I
DD
(Standby)
Supply current in Standby
mode (RTC disabled)
Independent watchdog
and LSI enabled
T
A
= -40 °C to 25 °C 1 1.7
Independent watchdog
and LSI OFF
T
A
= -40 °C to 25 °C 0.35 0.6
T
A
= 55 °C 0.47 0.9
T
A
= 85 °C 1.2 2.75
T
A
= 105 °C 2.9 7
(2)
I
DD
(WU from
Standby)
Supply current during
wakeup time from
Standby mode
-T
A
= -40 °C to 25 °C 1 - mA
1. Based on characterization, not tested in production, unless otherwise specified