Datasheet

Electrical characteristics STM32L151x6/8/B, STM32L152x6/8/B
90/131 DocID17659 Rev 9
SPI characteristics
Unless otherwise specified, the parameters given in the following table are derived from
tests performed under ambient temperature, f
PCLKx
frequency and V
DD
supply voltage
conditions summarized in Table 13.
Refer to Section 6.3.12: I/O current injection characteristics for more details on the
input/output alternate function characteristics (NSS, SCK, MOSI, MISO).
Table 49. SPI characteristics
(1)
1. The characteristics above are given for voltage Range 1.
Symbol Parameter Conditions Min Max
(2)
2. Based on characterization, not tested in production.
Unit
f
SCK
1/t
c(SCK)
SPI clock frequency
Master mode - 16
MHz
Slave mode - 16
Slave transmitter - 12
(3)
3. The maximum SPI clock frequency in slave transmitter mode is given for an SPI slave input clock duty
cycle (DuCy(SCK)) ranging between 40 to 60%.
t
r(SCK)
(2)
t
f(SCK)
(2)
SPI clock rise and fall
time
Capacitive load: C = 30 pF - 6 ns
DuCy(SCK)
SPI slave input clock duty
cycle
Slave mode 30 70 %
t
su(NSS)
NSS setup time Slave mode 4t
HCLK
-
ns
t
h(NSS)
NSS hold time Slave mode 2t
HCLK
-
t
w(SCKH)
(2)
t
w(SCKL)
(2)
SCK high and low time Master mode
t
SCK
/2
5
t
SCK
/2+
3
t
su(MI)
(2)
Data input setup time
Master mode 5 -
t
su(SI)
(2)
Slave mode 6 -
t
h(MI)
(2)
Data input hold time
Master mode 5 -
t
h(SI)
(2)
Slave mode 5 -
t
a(SO)
(4)
4. Min time is for the minimum time to drive the output and max time is for the maximum time to validate the
data.
Data output access time Slave mode 0 3t
HCLK
t
v(SO)
(2)
Data output valid time Slave mode - 33
t
v(MO)
(2)
Data output valid time Master mode - 6.5
t
h(SO)
(2)
Data output hold time
Slave mode 17 -
t
h(MO)
(2)
Master mode 0.5 -