Datasheet

Electrical characteristics STM32L100C6, STM32L100R8/RB
44/102 DocID024295 Rev 1
6.3 Operating conditions
6.3.1 General operating conditions
Table 11. Thermal characteristics
Symbol Ratings Value Unit
T
STG
Storage temperature range –65 to +150 °C
T
J
Maximum junction temperature 105 °C
Table 12. General operating conditions
Symbol Parameter Conditions Min Max Unit
f
HCLK
Internal AHB clock frequency 0 32
MHzf
PCLK1
Internal APB1 clock frequency 0 32
f
PCLK2
Internal APB2 clock frequency 0 32
V
DD
Standard operating voltage
BOR detector enabled,
(at power-on)
1.8 3.6
V
BOR detector disabled,
after power on
1.65 3.6
V
DDA
(1)
1. When the ADC is used, refer to Table 52: ADC characteristics.
Analog operating voltage
Must be the same voltage
as V
DD
(2)
2. It is recommended to power V
DD
and V
DDA
from the same source. A maximum difference of 300 mV
between V
DD
and V
DDA
can be tolerated during power-up and operation.
1.8 3.6 V
P
D
Power dissipation at
T
A
= 85 °C
(3)
3. If T
A
is lower, higher P
D
values are allowed as long as T
J
does not exceed T
J
max (see Table 61: Thermal
characteristics on page 98).
LQFP64 package 444 mW
TA Temperature range Maximum power dissipation –40 85 °C
T
J Junction temperature range -40 °C T
A
85°C –40 105 °C