Datasheet

DocID13586 Rev 16 37/90
STM32F101x8, STM32F101xB Electrical characteristics
89
Table 12. Maximum current consumption in Run mode, code with data processing
running from Flash
Symbol Parameter Conditions f
HCLK
Max
(1)
1. Based on characterization, not tested in production.
Unit
T
A
= 85 °C
I
DD
Supply current
in Run mode
External clock
(2)
, all
peripherals enabled
2. External clock is 8 MHz and PLL is on when f
HCLK
> 8 MHz.
36 MHz 28.6
mA
24 MHz 19.9
16 MHz 14.7
8 MHz 8.6
External clock
(4)
, all
peripherals Disabled
36 MHz 19.8
24 MHz 13.9
16 MHz 10.7
8 MHz 6.8
Table 13. Maximum current consumption in Run mode, code with data processing
running from RAM
Symbol Parameter Conditions f
HCLK
Max
(1)
1. Based on characterization, tested in production at V
DD
max, f
HCLK
max.
Unit
T
A
= 85 °C
I
DD
Supply current in
Run mode
External clock
(2)
, all
peripherals enabled
2. External clock is 8 MHz and PLL is on when f
HCLK
> 8 MHz.
36 MHz 24
mA
24 MHz 17.5
16 MHz 12.5
8 MHz 7.5
External clock
(2)
all
peripherals disabled
36 MHz 16
24 MHz 11.5
16 MHz 8.5
8 MHz 5.5